Water Analysis Report at QAR by the Marine Technology Program, Cape Fear Community College, Wilmington, NC

WATER ANALYSIS MEASUREMENTS

Queen Anne's Revenge

Vessel: R/V Snap Dragon     Date: 15 OCT 1998

Position: East Screw Eye     Technicians: D. Monaghan

Water Analysis Measurements
LOCAL TIMEBOTTLE #DEPTH [FT]TEMP [C]REFRACT pptSCT METER pptCOND uMhos/cm2pHDISSOLVE D OXYGEN PPMTIDE STATEREMARKS
10:206A0.524.035.034.048,1008.206.3EBBWeather: Sunny, clear, warm, light N wind calm sea
10:455E20.023.835.033.249,5008.186.2EBB 
11:476A0.523.535.033.049,0008.086.8EBB 
11:502E20.023.535.033.549,8008.097.0EBB 
12:516A0.523.535.033.048,5008.076.8SLACK 
13:055E20.023.536.034.050,0008.137.1SLACK 
14:026A0.523.535.033.048,0008.087.1SLACK 
14:045E20.024.036.034.050,0008.147.2SLACK 
NS        FLOODNS=No Sample
15.116A0.524.035.033.049,0008.127.1FLOOD 
15.305E20.024.036.034.2OS8.086.8FLOODOS=Off Scale

NOTES:

Field Meters Used Were: YSI Model 33 SCT Meter; YSI Model 57 Oxygen Meter; Fisher Accumet Model 955 mini pH meter; Leica # 10419 Refractometer

Calibrations were done before the first sample of the day and checked again at 13;05. No drift was noticed pH was calibrated using a buffer of 7

Dissolved Oxygen was air calibrated and salinity corrected

Surface sample was taken from SNAP DRAGON; Bottom temps are not: the temp was taken when sample was run, not when collected

All samples were analyzed within 5 minutes after being brought to boat

Sample frequency was dependent on divers schedule. When possible the surface and bottom samples were taken close to the same time

Sampling frequency was also changed to longer intervals after data was looked at and very little changes were noticed over time and tide state

Samples were collected during ebb, slack and flood tidal conditions